ARi® implant design
Industry Game-Changer for Anterior Atrophic Ridge
ARi® is a 4th generation implant that guarantees strong initial stability and osseointegration from basal bone – without bone volume restoration.
ARi® implant design is also more effective for post care, securing long-term stability, even if the alveolar bone is lost.
Clinic benefits
Implants can be placed in an anterior atrophic ridge, which was previously very difficult
Fast and simple surgical protocol without bone volume recovery surgery
Minimized maintenance burden after implantation
Patient benefits
Easier anthropic ridge function due to anterior teeth implant placement
More comfortable surgery and faster recovery
Reduced burden of other surgeries
ARi® design advantages
Guaranteed initial stability
KnifeThread® located in basal bone zone guarantees higher ISQ value immediately after implantation.
The application of MegaGen's special Deep & KnifeThread® design secures a high initial stability, even in the basal bone, immediately after implantation. It also increases resistance to compressive force while minimizing the occurrence of shear force.
Long-term stability, even if alveolar bone loss occurs
The thread section with XPEED® surface treatment, which is implanted in the non-degenerated basal bone, maintains stable strong osseointegration, ensuring long-term implant stability even if the alveolar bone is lost.
Facilitates soft tissue generation, prevents subsidence, and is more effective for post care
The unique implant body design supports cell adhesion, prevents continuous subsidence, averts complications such as peri-implantitis and fracture issues that can occur after restoration, and is easy to remove even when peri-implantitis occurs.
Wide range of implant sizes and connections
ARi® provides various design options, enabling stable implant placement in any situation.
Core size: Chosen based on masticatory force. (Usually based off of location of implant)
Thread depth: Chosen based on patient's bone quality.
Tapered Thread Length: Chosen based on patient's basal bone height.
Magic Cuff Height: Chosen based on patient's alveolar bone height.
10° External Conical Hex connection
The 10° external conical hex provides a strong bond with the abutment, facilitating conventional, digital, and thin ridge prosthetic options.
ARi implant design – feedback
Gita Zommerfelde-Antipina
Protēziste, implantoloģe (A WHITE Clinic)
“ARi left a very good impression as a solution focused on achieving strong primary stability, especially in challenging bone conditions. I find the concept of engaging basal bone particularly useful in atrophic cases where conventional implants would require additional augmentation. Overall, ARi seems to be a reliable option for simplifying treatment in compromised situations while maintaining predictable outcomes.”
Kaspars Stāmers
Mutes, sejas un žokļu ķirurgs (RSU Stomatoloģijas institūta Implantoloģijas klīnika)
“ARi left a very positive impression. It is a well-designed solution for cases of limited bone volume, where primary stability is provided by the basal bone, and in some cases the need for bone augmentation is also reduced.”
Tauri Narits
Mutes, sejas un žokļu ķirurgs (TÜK Stomatoloģijas klīnika, Igaunija )
"The ARi system has potential in complex bone conditions where the prognosis for regeneration is not good and alternative solutions are needed."
Regina Kuningas-Ott
Ķirurģe, implantoloģe (Hanzadent, Igaunija)
“I like that implants are available in a variety of small sizes – it expands the range of implantation options without bone augmentation.”